NEW PS100 N1201SA 140MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester In Case D1-005 | Электроника

Сохраните в закладки:

Цена:7 119,64RUB*

Количество:

Доставка в Эль-Монте, по России и СНГ


  • NEW PS100 N1201SA 140MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester In Case D1-005 | Электроника - Фото №1
  • NEW PS100 N1201SA 140MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester In Case D1-005 | Электроника - Фото №1
  • NEW PS100 N1201SA 140MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester In Case D1-005 | Электроника - Фото №1
  • NEW PS100 N1201SA 140MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester In Case D1-005 | Электроника - Фото №1
  • NEW PS100 N1201SA 140MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester In Case D1-005 | Электроника - Фото №1
  • История цены

    *История изменения цены! Указанная стоимость возможно, уже изменилось. Проверить текущую цену - >

    Месяц Минимальная цена Макс. стоимость Цена
    Aug-17-2025 9041.75 руб. 9222.8 руб. 9131.5 руб.
    Jul-17-2025 7333.34 руб. 7480.85 руб. 7406.5 руб.
    Jun-17-2025 8899.25 руб. 9077.0 руб. 8988 руб.
    May-17-2025 8828.51 руб. 9005.79 руб. 8916.5 руб.
    Apr-17-2025 7048.31 руб. 7189.29 руб. 7118.5 руб.
    Mar-17-2025 8685.74 руб. 8859.36 руб. 8772 руб.
    Feb-17-2025 8614.87 руб. 8786.58 руб. 8700 руб.
    Jan-17-2025 8543.79 руб. 8714.13 руб. 8628.5 руб.

    Новые товары

    Характеристики

    NEW PS100 N1201SA 140MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester In Case D1-005 | Электроника

    Описание товара

     

         

     

    1

     

    PS100/N1201SA 137.5MHz - 2.7GHz UV RF Antenna Analyzer SWR Meter Tester

        Specifications: 63241,64439 - Model No.:PS100 - Working Frequency: 137.5MHz~2.7GHz/35MHz~2.7GHz - Stepped Frequency: 1kHz     - Display: 2.4inch TFT with resolution 320*240(QVGA)     - Power Consumption <1.5W     - Charging Current: 400mA     - Charging Port: USB     - Auto Power Off: Settable 5-60minutes     - Measured Parameters: Impedance, reactance, SWR and S11     - Resolution: 4-digit readings      - Frequency Accuracy: <±10ppm     - Connector: SMA-K     - Impedance Measurement Range:    1Ω~1000Ω @frequency < 1300MHz;    1Ω~300Ω @frequency >1300MHz (Impedance Absolute Value)    - Standing Wave Measurement Range:   1~65 @frequency < 1300MHz;      1~10 @frequency >1300MHz  - S11(dB)Measurement Range: 0dB to -50dB     - Error (Single-point measurement):    For Impedance: < Impedance absolute value x 5%±0.1Ω (Z<200Ω, <1.5GHz)    For Standing Wave: < Effective readings x 10%±0.1    For S11: 0.1dB/5° (0dB to -10dB)    For (dB/°): 1dB/10° (-10dB to -20dB); 5dB/20° (-20dB to -40dB) - Directivity: < 35dB (140MHz to 2GHz after calibration); < 30dB (2GHz to 2.7GHz) - Scanning Points: 280 - Output Level: -18dBm  - Working Temperature: 0℃ to 40℃   - Atmospheric Pressure: 860hPa~1060hPa       Description:     - This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration     - The default boot into single-point measurement interface.     - Aluminum alloy shell prolongs its service life.   Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.       Startup & Shutdown:     - Hold down the CTRL key off press the power switch button.     - The boot state, long press (2S above) the switch button, after the release, the instrument will shut down     - The boot state, long press (2S above) the switch button, after the release, the instrument will shut down       Advice when Using:     - In order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.     - Try to use good quality RF cable and connectors.     - Calibrated cable marked to the next may not need to calibrate and direct use.     - Test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.     - Measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.     - If the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis.       Package Included: - 1 x PS100 Antenna Analyzer SWR Meter

     

    4

     

    2

     

    23456

    3

    11

     HTB1g6b9m25TBuNjSspmq6yDRVXaf23

    12

    810

     

    E

     

     



    Трекер стоимости


    Отзывы покупателей

    Новые отзывы о товарах

    Александра 18 Декабря 2021, 21:23 #

    Решила обновить свои наволочки для подушек. Мне понравились именно эти с рождественскими рисунками персикового цвета, что смотрятся прикольно и... Читать отзыв полностью...

    Карина_22 18 Декабря 2021, 21:45 #

    Всё идеально !Теперь у меня есть новые замечательные часы !))Только сегодня забрала их..очень эффектные и красиво смотрятся на руке ))вживую... Читать отзыв полностью...

    Андрей 18 Декабря 2021, 21:11 #

    Я занимаюсь ремонтом ноутбуков. Мне нужно было заменить клавиатуру на ноутбуке ASUS F80. Нашел подходящую клаву черной версии, как и... Читать отзыв полностью...

    Viki 19 Декабря 2021, 09:02 #

    Заказала эту рубашку! Классное качество. Все пришло в идеальном состоянии! Сейчас с удовольствием ношу. Размер идеально подошёл. Ткань после стирки... Читать отзыв полностью...

    Наталья 20 Декабря 2021, 18:23 #

    Решила своему мужу на день Святого Николая сделать хороший подарок и подарить трусы из хлопка. Мне понравилась эта модель трусов,... Читать отзыв полностью...

    Анна 19 Декабря 2021, 02:03 #

    Хочу сказать, что эта модель ноутбука мне сразу понравилась, благодаря хорошим высоким техническим характеристикам. Тем более доставили его... Читать отзыв полностью...

    Никита 18 Декабря 2021, 09:33 #

    Всегда мечтал приобрести некую прикольную штучку для своего душа. После нескольких часов поиска наткнулся на данный товар... Светодиодная насадка мне... Читать отзыв полностью...


    Отзывы о NEW PS100 N1201SA 140MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester In Case D1-005 | Электроника

    Данную страницу никто не комментировал. Вы можете стать первым.
    Введите символы или вычислите пример:
    captcha